Today s calcium silicate manufactured in north america is noted for its high compressive strength corrosion inhibiting properties and high temperature structural integrity.
Calcium silicate pipe insulation weight per foot.
Thermo 12 gold is a pre formed high temperature abuse resistant pipe and block insulation it has exceptional structural strength and can be used on operating systems that reach 1200 f 650 c.
Calculating heat loss by mark crombie chromalox posted.
Thermo 1200 is the only north american.
Calcium silicate pipe block insulation linear foot chart the following table shows the weight per linear foot of thermo 1200 for the purpose of estimating the load on pipe supports.
7 2 1 fit and closure when fitted to the appropriate size pipe by banding on 9 in.
Wednesday march 7 2018 8 13 am pst.
Insulation weights include allowances for wire ce.
Nominal size pounds per linear ft nominal size pounds per linear ft nominal size pounds per linear ft nominal size pounds per linear ft x1 1 2 x2 5 6x3 11 15x3 20.
Thermo 12 gold is composed of hydrous calcium silicate and is made with xox corrosion inhibitor a proprietary formula and process that inhibits corrosion to the outside surfaces of pipe and.
The listed thicknesses and weights of combination covering are the sums of the inner layer of diatomaceous earth at 21 ibs cu.
Calcium silicate pipe block insulation product data sheet thermo 1200tm thermo 1200 is a water resistant type i calcium silicate pipe and block insulation designed for applications that operate at temperatures up to 1200 f 650 c.
Pipe insulation support saddles the span load is determined by the total weight of the pipe filled with water covered with insulation and metal jacketing per linear foot multiplied by because it s a hydrous mass insulation using calcium silicate on cold applications isn t recommended.
Foot and the outer layer at 11 ibs cubic foot.
7 2 pipe insulation the following additional dimensional tolerances apply only to calcium silicate pipe insulation sup plied as half sections.
Insulation weights are based on 85 magnesia and hydrous calcium silicate at 11 ibs cu.
Preformed block preformed pipe and board.
Also for pipe insulation the outer area of q m1c1 m 2 c2 mncn δt 3 412 where n is the number of materials each material s weight visit document.
For 4 pipe with 4 nominal thickness insulation f 77.
To simplify heat loss calculations pipe heat loss is based on the heat loss per linear foot rather than the entire area of any given length.
Then multiply f by the density of the insulation in pounds per cubic foot.
Read full source.
April 7 2018.
It is manufactured and sold in three different forms.
Stanwood pr newswire effective immediately thermal pipe shields tps a privately held mechanical insulation supply company with three generations of industry engagement dating.
229 mm centers the longitudinal seams on both sides of the pipe insulation shall close to within.